-40%
20 Microns ULV FOGGING MACHINE AEROSOL DISINFECTOR FUMIGATOR 6 LTRS
$ 413.82
- Description
- Size Guide
Description
OPERATION THEATRE ULV FOGGERFOR ODOR CONTROL & DISINFECTION
(Specialised for OT Sterilisation)
Model: ADVANCE:
Product Description:
Fogger Machine consume negligible power and virtually require no maintenance. Provides operation theater fumigator to suit the requirements of each and every medical profession.These operation theater fumigator are used in most of the Indian hospitals and dispensaries.
USES OF ULV FOGGING MACHINE:
ULV foggers in opposite do not use extensive heat in fogging process, so they can be used indoors without fire risks. Also, ULV foggers produce almost invisible fog and allow to adjust particle size, so they can be used in more applications than thermal foggers. ULV foggers are used:
In any indoor place. As mentioned above, ULV foggers use cold fogging techniques, so they are safe to use indoors.
For odor control and disinfection. ULV foggers are often used to disinfectant houses and large warehouses as well as control unpleasant odors in such areas. ULV fogger can be left to work automatically and there isn’t need for a person to operate the fogger all the time as with thermal foggers.
To get rid of molds. ULV foggers are also used with special chemicals to get rid of molds in indoor areas.
On plants and greenhouses. Because ULV foggers allow to adjust particle size, they can also be used outdoors or in greenhouses to spray different solution on plants.
Indoor and outdoor pest control. ULV foggers are the best pest control method for indoor areas, however, they are also used outdoors, for example to control mosquitoes. Although ULV foggers cannot produce such small particles as thermal foggers, some ULV foggers can produce particles from 5-20 micron range, which is effective for mosquito control. One disadvantage with using ULV foggers outdoors is that they produce almost invisible fog, so it is going to be harder to control the direction of the fog.
Advantages:
- Provides complete asepsis within 30 to 60 minutes.
- Cleaning with detergent or carbolic acid not required.
- Formalin fumigation not required.
- Shutdown of O.T. for 24 hrs. not required.
Method of Use:
Measure the qulaity of formalin/fogger concentration and water suggested and pour into the equipment. Place the machine inside the room to be sterilized or disinfected and switch it 'ON' to 5 amp. electrical point. Keep the operation continued for app. 45 minutes and switch 'OFF' the machine. Leave the room fumed for minimum 6 hrs. in a closed state and then exhaust the fumes. Precautions For disinfector of the air conditioned operation theatures and rooms, switch 'OFF' the air conditioner or close the duct if it is centrally air conditioned before the disinfection process is started.