2L Lab Crystalliser Equipment Rotary Evaporator with Rotary flask and Condenser
$ 675.84
- Description
- Size Guide
Description
This Item will be shipped within 5-14 business days via DHL after we have received payment as it will need careful QC and packaging. (Please be understanding and communicate regarding concerns, thank you)2L Lab Crystallizer Equipment Rotary Evaporator/ Rotovap with Rotary flask and Condenser
Rotating Evaporators are a necessary apparatus used for concentration,
crystallization, separating and recovery in biochemistry, organic chemistry, medical
experiments
and
scientific research by laboratories, institutes and universities.
DHL free shipping
1. Specifications:
1) Capacity of rotating bottle: 50---2000 ml
2) Rotating speed: 0----150 r.p.m. Step-less speed change device
3) Distance of main machine between up and down: 0---150 mm
4) Temperature range of Heating Tank: ambient temperature to 100ºC
5) Vacuum rate: More than 0.096Mpa.
6) Power Supply: AC 220V ±10%, 60 Hz, Input Power: 1.5 KW
7) Dimensions: 370x530x750 mm; Weight: 23 kg
2.Feature:
1) Auto-rising and dropping by touching key, the main machine can also be risen & dropped by the reserve wheel.
2) The function of Vacuum is good: more than 0.096Mpa
3) Auto-temperature controller is displayed by digital.
4) High evaporating rate of vertical condenser. The condensation pipes in the condenser are made of Snake-shaped dual-return loop glass pipe.
3.Installation:
1) Before installation, at first the angle of the rotating motor should be adjusted into 30º in dining to the right. When you adjust the angle of rotating motor, you must hold the motor. After you completed the adjustment, you must lock up the motor. Then install the Vertical Pole(15) on the holding fixation plate. At same time do not tighten the screw.
2) Main Axle of Installation: Before the main axle(1) is installed, every connector, every sealing place and every sealing washer must be clean up and applied some vacuum grease to guard against leakage, Put the Nut(2) in the main axle(1), then put the pressing washer(3) in the slot of main axle, then insert the main axle into the Rotating sleeve(4). When you tighten the Nut(2), at same time you should insert the small six-angle-spanner into the hole under the rotating motor.
3) Four–Path-Bottle of installation: First step, put the big plastic Nut(9) in the neck of the Four-Path-Bottle, then the spring ring so do. Then put the Sealing Washer(7) in the Main Axle(1), then the PTFE Sealing Washer(8) so do according to the display of the drawing. At last connect the Big Plastic Nut(9) to the Rotating Motor(6).
4) The Condensation Bottle(16) of installation: At first put the Stainless Steel Clip(18) in the Condensation Bottle(16). Then put the Condensation Bottle(16) into the Four-Path-Bottle(11) and connect them tightly. Then put the Stainless Steel Clip(18) in the Vertical Pole(15). After adjust them on the suitable place, then tighten the Screw(14).. At last install the Evaporating Bottle and Collecting Bottle.
Illustrated Instruction for Installation
16. Condensation Bottle
17. Stainless Steel Clip
4. Operation
1) Adjustment of up and down
a. manual adjustment is operated by the Wheel
b. Auto-Adjustment is operated by the up-down touching key.
2) There are two outer-connector on the bottom of condensation bottle, one for inputting condensation water, another for outputting water. There is a vacuum connector on the top for vacuumizing
3) Before operation, at first turn the speed switch to the left to minimum. Turn on the power supply. The signal lamp is lit. Then turn the speed switch to right to your requested speed.
5.
Operation of Temperature Controller
1) After turn on the meter, the screen displays inputting type: the above-listed displays Inp., the
below-listed displays graduation number. After 4 seconds, the above-listed displays the
measurement range upper-limit, the below-listed displays low-limit. After 4 seconds again,
the above-listed displays measuring value, the below-listed displays setting up value. The
machine begins normal working.
2) Setting up the temperature value: Press the key ‘╓’, the upper-listed displays ‘SP’, press the
key ▲ or ▼to make the below-listed display set-up value. Then press the key ‘╓’ to make
the meter return to the standard mode.
3) Setting up the controlling parameters
Continuous press the key ‘╓’ more than 4 seconds, the above-listed will display the different
Controlling parameters ( Seeing the Controlling Parameters List). Then press the key ‘╓’ to make the meter return to the standard mode.
4) If the below red display shows ‘000’, the thermoelement was connected wrong.. If the above
red display shows ‘000’, the thermoelement was opened circuit or the temperature exceeds
the Limit.
5) Delete the old parameters and stabilize the new parameters: Continuous press the key ▲ more than 20 seconds, Lamp AT begins sparkling. After the temperature shows one or two fluctuation, the parameters were deleted. The Lamp AT was out. Then set up the new parameters
The Function Parameters List
Prompting
Signal
Name
Setting Up
Range
Description
Value at
Factory
AL
Alarm of setting
Up
-200---800
℃
AL>0 is upper limit alarm. AL<0 is low limit alarm.
Output is Auto-changed. Actual alarm point=SP+AL
50
AL
rt
Measuring
Value revise
-100---100ºC
Revise the value of thermoelement.
0
RT
Ar
Over-heat
control
0---100ºC
Reduce the value of Ar to control over-heat. When SP is
Changed, the value of Ar should be re-set. P=0, Ar is not
useful. Ar=0, the actual value of Ar is 0.4ºC. Cr=0, the
time proportion of Ar should be re-set.
30
Ar
P
Temperature
Proportion
Range
0---400ºC
The value of P is bigger, the proportion function is
smaller and the systems gain is lower. The value of P is
too small, the temperature will be fluctuated.
30
P
T
Control Cycle
1---100 Sec.
The output of relay should be more than 20seconds.
T of Relay or SCR out of the machine = 3 Sec
3
T
Cr
Systems
Constant
1---999
In usual practice the inertia of material is big, the value
of Cr should be much big. P≠0, Cr=0, the meter is under
the status of time proportion control
240
Cr
LC
Cipher Code
Lock
0---2
LC=0: All the parameters can be amended. LC=1: Only
the value of SP can be amended. LC=2: All the
parameters can not be amended.
1
LC
WARNING: Above parameters have been adjusted into the best condition. Please do not amend Them.
This item will be shipped from Hong Kong or Shenzhen. Should there be an issue with this item please contact us so we can try to rectify. Don't forget to leave a positive comment as we will do likewise for you.
About Shipping:
1.We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay.
2.Items will be shipped within 5-14 business days when we received payment.