-40%
High Temperature Circulator 20L oil bath Room Temp~300°C Reactor Evaporator Y
$ 287.83
- Description
- Size Guide
Description
High Temperature Circulator oil bath 50L Digital display room~300°C 15L/minNOTE: 1. The voltage is 220V 50Hz, if you power supply is 110V, please kindly make sure you have the transformer to enable it work .
2. The viscosity of the oil or material should no more than 100 mPa.s or centipoises. The 50mPa.s dimenthyl-silicon oil
is optimum heating material.
3. If you use the water, please choose pure water so that it will be
encrusted.
4
. One Year Warranty!!!
Introduction
This high temperature circulator is a new design of a high temperature heat source,
suitable for
jacketed reactor, chemical reaction, high temperature distillation, semiconductor
industry
.
Feature
1 High temperature circulator
is suitable for fermenter,jacketed glass reactor
and other
things.
2 Outside circulation could
rise the temperature in the jacket
,therefore materials in
which would react.
3 Water and oil temperature was up to 300 degrees.
4
Temperatur fluctuation is in ±0.2°C.
5 Resolution of
digital display is 0.1°C.
6 Flow of outer circulation is
7~15L/min.
7
Auto-alarm
of over temperature.
8
Stop heating when the temperature is over
.
9 There are
six models
that can be chose:
5L,10L,15L,20L,30L,50L
.
10 Our high temperature adopts the newest control technique,easy to operate,
great
stability and high
precise
.
11
The PID can be set by yourself.
12 LED double window respectively
digital temperature measurement and temperature setting
value.
13
Microcomputer intelligent
could modify the error of measuring value.
Operation steps
1
Pour liquid into the sink
,the distance between liquid level and the working platen should not
less
than 20mm.
2
Chose oil for the liquid
.The initial temperature of the oil must higher than working
temperature,
range of which is
more than 15°C.
3
Connect the out circulator pump with external equipment
,which includes jacketed
reactor, chemical reaction, high temperature distillation or other equipment.First
connect
o
utlet pipe with the inlet pipe
of external equipment,then connect inlet pipe of
the
circulator pump
with the outlet pipe of the external equipment
.
4
Turn on the power,then switch the“POWER”button and the”CIRCULATOR
”button on.
Note
1 There must be
liquid in the tank
before switch the “POWER”button.
2 The power supply should be
AC 220V/50Hz
,and it should be connected with ground.(If your standard power is 110v, please kindly contact with us).
3 This high temperature circulator should be placed at dry and ventilated places,preventing
heat and damps.There should be
no objects around its back and sides in 300mm
.
4 If you
do not use
it temporary,please
turn off all buttons and the power
.
Parts and components
1 One circulator
2 One power line
3 One cover board
4 One piece of specification
5 One piece of certification
6 One piece of warranty car
Technical
details
Model
Volume(
L
)
Tempreture(
°C
)
Temperature fluctuations
(
°C
)
Flow
(L/min)
Tank size
(mm)
Tank Depth(mm)
GX-2005
5
Normal~300
±0.2
8
240*150*150
150
GX-2010
10
10
280*190*200
200
GX-2015
15
15
280*250*200
200
GX-2020
20
15
280*250*280
280
GX-2030
30
15
400*330*230
230
GX-2050
50
15
500*330*300
300